Configuring Communication
45
NXD/T-1200V Wall/Flush Mount Touch Panel
Configuring Communication
Overview
Communication between the Modero panel and the Master is done using either
USB
or
ETHERNET
(
DHCP or Static
IP
). Ethernet communication can be achieved through either a direct connection (Ethernet) or through the use of the
optional NXA-PCI80211G wireless interface card.
Modero Setup and System Connection
1.
Press the grey Front Setup Access button for
3 seconds
to open the Setup page (FIG. 50).
2.
Press the
Protected Setup
button (located on the lower-left of the panel page) to open the Protected Setup page and
display an on-screen keypad.
3.
Enter
1988
into the Keypad’s password field and press
Done
when finished.
4.
Press the red
Device Number
field to open the Device Number keypad (FIG. 51).
5.
Enter a
Device Number
value for the panel into the Device Number Keypad
. The default is 10001 and the range is
from 1 - 32000.
6.
Press
Done
to close the keypad, assign the number, and return to the Protected Setup page.
USB input devices must be plugged into the rear or side USB connectors before the
G4 panel is powered-up. The panel will not detect a USB connection of this type until
after the unit cycles power.
Before commencing, verify you are using the latest NetLinx Master and Modero panel
firmware. Verify you are using the latest versions of AMX’s NetLinx Studio and
TPDesign4 programs.
FIG. 50
Setup page
Battery Base button doesn’t appear
until NXT is connected to a BASE/B
Connection Status
Red
Connection Status icon -
Green
Connection Status icon -
indicates no connection to a Master
indicates communication to a Master
Yellow
Connection Status icon -
indicates an unreliable network
connection
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.
When using multiple panels within a NetLinx System, remember to assign unique
Device Number values to each panel so that all assigned panels appear in the
System listing for the target Master.
Summary of Contents for Modero NXD-1200V
Page 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...
Page 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...
Page 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...
Page 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...
Page 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...
Page 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...