Touch Panel Accessories
6
NXD/T-1200V Wall/Flush Mount Touch Panel
Installing the NXA-AVB/ETHERNET
A 12 VDC-compliant power supply can indirectly provide power to a Modero panel by routing power through the NXA-
AVB/ETHERNET Breakout Box. FIG. 4 shows a sample wiring configuration using both an indirect or direct power
connection for a video-capable Modero panel.
A 12 VDC-compliant power supply can also directly provide power through the unit to a target Modero panel. FIG. 5
shows a sample wiring configuration for a non-video capable Modero panel.
Use a standard CAT5 Ethernet cable to provide both communication and 10/100 network connectivity between the panel,
NXA-AVB/ETHERNET, NetLinx Master, and the network.
NXA-AVB/ETHERNET Specifications (Cont.)
Included Accessories:
• Two 2-pin Phoenix connectors (41-5025)
• 4-pin Phoenix connector (41-5047)
• 6-pin Phoenix connector (41-5063)
• Rack Mount Kit (KA2250-40) with mounting bracket (62-2254-02)
Other AMX Equipment:
• AC-RK Accessory RackMount Kit (
FG515
)
• Modero Table Top Cable (CA2250-50)
FIG. 4
Sample wiring configuration on video-capable panels using this breakout box
FIG. 5
Sample wiring configuration using CA Modero panels
NXD/T Video-capable
Ethernet In
12 VDC power
(RJ-45)
Video In
(BNC)
Mic Out
(4-pin captive-wire)
Audio In
(6-pin captive-wire)
NXA-AVB/ETHERNET
Power
supplied via
NXA-AVB box
Audio/Video
(CAT5)
Line Level out
(to amplifier
or VOL card)
Touch Panels
or
Direct
Connect
Breakout Box
Ethernet
(
rear
)
(
front
)
(CAT5)
supply
Indirect
Connect
12 VDC power
supply
Direct
connect
NXD/T Non-video capable
Ethernet
(CAT5)
Touch Panels
12 VDC power
Audio (CAT5)
between the
NXA-AVB/ETHERNET
Breakout Box
supply
The breakout box unit can be mounted on either a horizontal flat surface or into an
equipment rack (by removing the front screws and attaching it to an optional AC-RK).
The power supply being used on the NXA-AVB/ETHERNET is dependant on the
power requirements of the target touch panel.
Summary of Contents for Modero NXD-1200V
Page 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...
Page 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...
Page 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...
Page 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...
Page 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...
Page 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...