Installation Procedures: NXD-1200V Panels
38
NXD/T-1200V Wall/Flush Mount Touch Panel
11.
Place the magnetic faceplate (
A
in
FIG. 40) back onto the main NXD unit (
B
in
FIG. 40).
Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective openings on the
front bezel/faceplate.
12.
Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their respective locations on
either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or NetLinx Master.
13.
Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.
Installing the NXD into a Flat Surface using #4 screws
Mounting screws (#4, not included) are secured through circular holes located at the left and right sides of the NXD
panel.
The most important thing to remember when mounting the NXD is that the outer frame (Mounting Tabs)
must be installed flush against the mounting surface.
It is recommended that you cutout the surface slightly smaller than what is outlined in the installation
drawings so that you can make any necessary cutout adjustments.
1.
Prepare the area by removing any screws or nails from the surface before beginning the cutout process.
2.
Cut out the surface for the
12-inch Wall Mount
using the dimensions shown in FIG. 41.
3.
Remove the magnetic faceplate/bezel (
A
in
FIG. 42) from the main NXD unit (
B
in
FIG. 42) by gripping the
faceplate and pulling with gentle outward force.
FIG. 41
NXD-1200V Wall Mount panel dimensions using #4 mounting screws
FRONT BEZEL
SECURE UNIT WITH #4 SCREWS.
SURFACE (PODIUM, DESK, ETC.).
WHEN MOUNTING UNIT TO A SOLID
THESE 4 HOLES ARE ONLY REQUIRED
CUTOUT
Summary of Contents for Modero NXD-1200V
Page 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...
Page 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...
Page 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...
Page 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...
Page 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...
Page 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...