Installation Procedures: NXD-1200V Panels
35
NXD/T-1200V Wall/Flush Mount Touch Panel
The USB connectors can be from either a USB extension cable, or a wireless USB RF transmitter.
4.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying power. Verify
the panel is receiving power and functioning properly to prevent repetition of the installation.
5.
Disconnect the terminal end of the power cable from the connected power supply.
6.
Carefully slide the main unit (
B
in FIG. 38) into the conduit box, so the Mounting Tabs lie flush against the conduit
box (
C
in FIG. 38).
7.
Insert and secure the four securing #4-40 Mounting Screws into their corresponding holes located along the sides of
the NXD (FIG. 37 and FIG. 38).
8.
Place the magnetic faceplate (
A
in
FIG. 38) back onto the main NXD unit (
B
in
FIG. 38).
Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective openings on the
front bezel/faceplate.
9.
Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their respective locations
(
outside the conduit box
) on either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or NetLinx Master.
10.
Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.
Installing the NXD into drywall using Expansion Clips
Expansion clips are mounted through the four oval holes located at the top and bottom of the panel. As the screw is
tightened, the clip bends toward the insertion hole and into the wall. This bending creates a "grip" on the wall by either
pressing onto the wall or by securing the drywall between the housing and the drywall clip.
The most important thing to remember when mounting the NXD is that the outer frame (Mounting Tabs) must be
installed flush against the mounting surface.
1.
Prepare the area by removing any screws or nails from the drywall before beginning the cutout process.
2.
Cut out the surface for the
12-inch Wall Mount
using the dimensions shown in FIG. 39. Be sure to cut out the four
notches along the top and bottom areas to accommodate the four drywall expansion clips (provided).
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the conduit box.
Summary of Contents for Modero NXD-1200V
Page 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...
Page 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...
Page 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...
Page 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...
Page 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...
Page 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...