Table A-10
Status Commands (Continued)
Set Operation
Status
Shutdown
Positive
Transition
Register
[:]STATus[<channel>]:OPERation
:SHUTdown:PTRansition
Access the Operation
Shutdown Positive Trans
Filter Register. See Table
5-12 on page 5-41.
?|<Transition Flags -
(0–65535)>
Yes
Query
Operation
Status
Shutdown
Protection
Condition
Register
[:]STATus[<channel>]:OPERation
:SHUTdown:PROTection:CONDition?
Query the Operation
Shutdown Protection
Condition Register. See
Table 5-12 on page 5-41.
Yes
Set Operation
Status
Shutdown
Protection
Enable Register
[:]STATus[<channel>]:OPERation
:SHUTdown:PROTection:ENABle
Access the Operation
Shutdown Protection Enable
Register. See Table 5-12 on
page 5-41.
?|<Enable Flags -(0–
65535)>
Yes
Query
Operation
Status
Shutdown
Protection
Event Register
[:]STATus[<channel>]:OPERation
:SHUTdown:PROTection[:EVENt]?
Query the Operation
Shutdown Protection Event
Register. See Table 5-12 on
page 5-41.
Yes
Set Operation
Status
Shutdown
Protection
Negative
Transition
Register
[:]STATus[<channel>]:OPERation
:SHUTdown:PROTection:NTRansition
Register. See Table 5-12 on
page 5-41.
?|<Transition Flags -
(0–65535)>
Yes
Summary of Contents for Sorensen XG
Page 2: ......
Page 22: ...Contents xx M370430 01 Rev B ...
Page 96: ...Local Operation 3 48 M370430 01 Rev B Figure 3 5 Series Operation ...
Page 102: ...Local Operation 3 54 M370430 01 Rev B ...
Page 210: ...Remote Operation 5 76 M370430 01 Rev B ...
Page 276: ...Communications Options 6 66 M370430 01 Rev B ...
Page 378: ...Rack Mount Options and Installation Instructions D 12 M370430 01 Rev B ...
Page 381: ......