Protection Sub-Register Commands
Query Protection Event
SCPI command:
[:]STATus[<channel>]:OPERation:SHUTdown:PROTection[:EVE
Nt]?
Query Protection Condition
SCPI command:
[:]STATus[<channel>]:OPERation:SHUTdown:PROTection:COND
ition?
Enable Protection Sub-Register
SCPI command:
[:]STATus[<channel>]:OPERation:
SHUTdown:PROTection:ENABle <status-enable>
Query format:
[:]STATus[<channel>]:OPERation:SHUTdown:PROTection:ENAB
le?
Set Protection Positive Transition Filter
SCPI command:
[:]STATus[<channel>]:OPERation:SHUTdown:PROTection:PTRa
nsition <stats-enable>
Query format:
[:]STATus[<channel>]:OPERation:SHUTdown:PROTection:PTRa
nsition?
Set Protection Negative Transition Filter
SCPI command:
[:]STATus[<channel>]:OPERation:SHUTdown:PROTection:NTRa
nsition <status-enable>
Query format:
[:]STATus[<channel>]:OPERation:SHUTdown:PROTection:NTRa
nsition?