Analog Programming (APG) and Isolated Analog Programming (ISOL)
4-10
M370430-01 Rev B
Voltage-Controlled Voltage APG Setup
Activating APG Voltage Mode
To activate APG voltage mode using an external voltage source:
1.
Turn the 9-position mode control to the VAP position or press
the rotary Adjust/Enter control if the mode control is already
at the VAP position.
is displayed on the output voltage display.
2.
Turn the rotary Adjust/Enter control to select
(voltage
source from non-isolated connector).
3.
Press the rotary Adjust/Enter control to commit the selected
mode.
is displayed on the output voltage display.
4.
Once the desired level has been selected, press the rotary
Adjust/Enter control to commit the change.
The display will return to the normal display.
Deactivating APG Voltage Mode
To deactivate the APG voltage mode:
1.
Turn the 9-position mode control to the VAP position or press
the rotary Adjust/Enter control if the mode control is already
at the VAP position.
2.
is displayed on the output voltage display.
3.
Turn the rotary Adjust/Enter control to select
.
4.
Press the rotary Adjust/Enter control to commit the change.
The display will return to the normal display.
Summary of Contents for Sorensen XG
Page 2: ......
Page 22: ...Contents xx M370430 01 Rev B ...
Page 96: ...Local Operation 3 48 M370430 01 Rev B Figure 3 5 Series Operation ...
Page 102: ...Local Operation 3 54 M370430 01 Rev B ...
Page 210: ...Remote Operation 5 76 M370430 01 Rev B ...
Page 276: ...Communications Options 6 66 M370430 01 Rev B ...
Page 378: ...Rack Mount Options and Installation Instructions D 12 M370430 01 Rev B ...
Page 381: ......