Calibration and Troubleshooting
7-10
M370430-01 Rev B
Non-isolated Analog Programming Calibration
Prior to this, the main output must be calibrated first.
Important:
In calibration commands, when + or - keys are expected, any other
key will exit from the calibration mode.
Non-isolated Voltage Monitoring Calibration
Important:
For maximum accuracy at a specific APG level, follow the
calibration procedure again but use the intended operating voltage level in steps
3 and 8.
To calibrate the non-isolated voltage monitoring:
1.
Disconnect the load and connect the voltmeter to the output.
2.
Connect the voltmeter to the non-isolated voltage monitoring
output lines (J1.13 - J1.7).
3.
Set the Voltage APG level to 4 V. Send the SCPI command:
SYST:COMM:APR:LEV 4
4.
Set the input source as Local. Send the SCPI command:
SYST:REM:SOUR LOC
5.
Set the main output voltage to 100% by sending the
command:
SOUR:VOLT <ModelVolt>
or use the rotary adjust/Enter control.
6.
Turn the main output On by pressing the OUTPUT ENABLE
Main button on the front panel or send the command:
:OUTP ON
The OUTPUT ENABLE Main button will illuminate.
7.
Enter interactive calibration mode by sending the SCPI
command:
CAL:MON
8.
Press on the terminal keys - or + to reduce or increase
monitoring value. Adjust the monitoring value displayed on
the voltmeter that was set up in Step 1 to read as close as
possible to 4.000 V.
9.
Press any key other than the + or - keys to exit from
interactive calibration mode.
Non-isolated Current Monitoring Calibration
Important:
For maximum accuracy at a specific APG level, follow the
calibration procedure again but use the intended operating voltage level in steps
3 and 9.
Summary of Contents for Sorensen XG
Page 2: ......
Page 22: ...Contents xx M370430 01 Rev B ...
Page 96: ...Local Operation 3 48 M370430 01 Rev B Figure 3 5 Series Operation ...
Page 102: ...Local Operation 3 54 M370430 01 Rev B ...
Page 210: ...Remote Operation 5 76 M370430 01 Rev B ...
Page 276: ...Communications Options 6 66 M370430 01 Rev B ...
Page 378: ...Rack Mount Options and Installation Instructions D 12 M370430 01 Rev B ...
Page 381: ......