![background image](http://html1.mh-extra.com/html/ametek/sorensen-xg/sorensen-xg_operation-manual_2931320339.webp)
M
3
7
0
4
3
0
-01
R
e
v
B
A
-35
A
S
CP
I Co
mm
a
nd
R
efe
re
nc
e
Table A-10
Status Commands (Continued)
Service
Request
Enable
(*SRE,*SRE
?)
[:]STATus[<channel>]:SREQuest:ENABle
Access Service Request
Enable Command.
?|<Enable Flags - (0 –
255)>
Yes
[:]STATus[<channel>]:CLEar
Clears all the Status Data
Structures.
Table A-11
Protection Commands
Function
SCPI Command
Description
Parameter and
Range
Query
Enable the
interlock
functionality.
[:]SENSe[<channel>]:PROTection:INTerlo
ck[:STATe]
Control the Enable/Disable
state of the Interlock System.
?|ON|OFF
Yes
Table A-12
Auto Sequence Commands
Function
SCPI Command
Description
Parameter and Range
Query
Delete all
sequences.
[:]PROGram[<channel>]:DELete:ALL
Erases the sequence
currently in memory.
N/A
Change Auto
Sequence
operating state.
[:]PROGram[<channel>]:STATe
Access to the run state of
the Sequence.
?|RUN|STOP|PAUSE
Yes
Program
selected
sequence end
action.
[:]PROGram[<channel>]:REPeaT
Sets the number of times to
repeat the sequence.
?|<Repeat count (1–
65534)>INFinity
Yes
Summary of Contents for Sorensen XG
Page 2: ......
Page 22: ...Contents xx M370430 01 Rev B ...
Page 96: ...Local Operation 3 48 M370430 01 Rev B Figure 3 5 Series Operation ...
Page 102: ...Local Operation 3 54 M370430 01 Rev B ...
Page 210: ...Remote Operation 5 76 M370430 01 Rev B ...
Page 276: ...Communications Options 6 66 M370430 01 Rev B ...
Page 378: ...Rack Mount Options and Installation Instructions D 12 M370430 01 Rev B ...
Page 381: ......