![background image](http://html1.mh-extra.com/html/ametek/sorensen-xg/sorensen-xg_operation-manual_2931320352.webp)
Sp
e
c
ifi
c
a
ti
o
n
s
C
-6
M3
70
43
0
-01
R
ev
B
Electrical Specifications for XG/XTR Family, 1700 W
Table C-3
XG 1700 Watt Electrical Specifications for 6 V to 600 V Models
Models
6-220
8-200
12-140
20-84
33-50
40-42
60-28
80-21
100-17
150-11.2
300-5.6
600-2.8
Output Ratings:
Output Voltage
1
6 V
8 V
12 V
20 V
33 V
40 V
60 V
80 V
100 V
150 V
300 V
600 V
Output Current
2
220 A
200 A
140 A
84 A
50 A
42 A
28 A
21 A
17 A
11.2 A
5.6 A
2.8 A
Output Power
3
1330 W
1610 W
1690 W
1690 W
1660 W
1690 W
1690 W
1690 W
1710 W
1690W
1690 W
1690 W
Line Regulation:
Voltage
4
(0.005% of rated
output v2 mV)
2.3 mV
2.4 mV
2.6 mV
3.0 mV
3.7 mV
4 mV
5 mV
6 mV
7 mV
9.5 mV
17 mV
32 mV
Current
5
(0.01% of rated
output c2 mA)
24 mA
22 mA
16 mA
10.4 mA
7 mA
6.2 mA
4.8 mA
4.1 mA
3.7 mA
3.12 mA
2.56 mA
2.28 mA
Load Regulation
Voltage
6
(0.005% of rated
output v 2 mV)
2.3 mV
2.4 mV
2.6 mV
3.0 mV
3.7 mV
4 mV
5 mV
6 mV
7 mV
9.5 mV
17 mV
32 mV
Current
7
(0.02% of rated
output c5 mA
49 mA
45 mA
33 mA
22 mA
15 mA
13 mA
10.6 mA
9.21 mA
8.4 mA
7.2 mA
6.1 mA
5.6 mA
Output Ripple (rms, 300 kHz):
Voltage
8 mV
8 mV
8 mV
8 mV
8 mV
8 mV
8 mV
8 mV
8 mV
10 mV
25 mV
50 mV
Current
8
400 mA
340 mA
240 mA
150 mA
120 mA
90 mA
70mA
50 mA
40 mA
32 mA
20 mA
12 mA
Output Noise (p-p, 20 MHz):
Voltage
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
80 mV
80 mV
100 mV
150 mV
250 mV
Maximum Recommended Remote
Sense Line Drop Compensation per
Line
9
1 V
1 V
1 V
1.5 V
2 V
2 V
3 V
5 V
5 V
5 V
5 V
5 V
Up-prog. Response Time,
0~Vmax
10
60 ms
60 ms
60 ms
60 ms
60 ms
60 ms
60 ms
100 ms
100 ms
100 ms
150 ms
250 ms
Down-prog. Response Time: Full
Load
50 ms
50 ms
50 ms
50 ms
50 ms
50 ms
50 ms
80 ms
100 ms
150 ms
150 ms
250 ms
Down-prog. Response Time: No
Load
300 ms
400 ms
500 ms
600 ms
700 ms
800 ms
900 ms
1000 ms
1200 ms
1800 ms
2200 ms
3500 ms
Over-Voltage Trip Point
0.5–7.5 V
0.5–10 V
1–15 V
1–24 V
2–39 V
2–44 V
3–66 V
3–95 V
3–125 V
3–180 V
5–330 V
5–660 V
Summary of Contents for Sorensen XG
Page 2: ......
Page 22: ...Contents xx M370430 01 Rev B ...
Page 96: ...Local Operation 3 48 M370430 01 Rev B Figure 3 5 Series Operation ...
Page 102: ...Local Operation 3 54 M370430 01 Rev B ...
Page 210: ...Remote Operation 5 76 M370430 01 Rev B ...
Page 276: ...Communications Options 6 66 M370430 01 Rev B ...
Page 378: ...Rack Mount Options and Installation Instructions D 12 M370430 01 Rev B ...
Page 381: ......