Analog Programming (APG) and Isolated Analog Programming (ISOL)
M370430-01 Rev B
4-7
4
Making Control Connections
CAUTION: Equipment damage
Before making connections from external circuits to the Analog Programming
Connector, turn the front panel power switch to Off and wait until the front
panel displays are not illuminated.
CAUTION: Equipment damage
Program/monitor signal and return are internally connected to the power supply
negative output (-S). Do not attempt to bias these away from that potential.
To connect the output wires to the APG and DC output connector:
1.
Insert a 3/32 inch slot-head screwdriver into the
orange-colored box of the connector until the end of the
spring is reached. See Figure 4-2.
2.
Hold the connector open and insert the applicable output
wire.
3.
Remove the screwdriver.
Figure 4-2
Inserting Screwdriver into Spring Terminal Block
Figure 4-3
APG and DC Output Connector