Introduction
In addition to the front panel interface, the XG/XTR can be remotely
controlled through the various remote interfaces. The XG/XTR
implements the SCPI standard as its command line interface for
remotely controlling the power supply. Additionally, a small subset of
legacy commands has been provided for ease of use and backwards
compatibility. All of the remote interfaces use the same command line
interface.
This chapter is divided into two parts:
Hardware and Connection Setup provides information on how to
setup a connection to the different remote interfaces available on
the XG/XTR. The remote interfaces covered include RS-232,
RS-485, USB, and GPIB.(The LAN/ENET option is set up
differently between the XG/XTR 850 Watt models and the 1500
and 1700 Watt models. See either SETTING UP XG/XTR 850
WATT MODELS or SETTING UP XG/XTR 1500 and 1700
WATT MODELS in Section 6
“Communications Options”
, as
applicable).
Command Line Interface and SCPI explains how to send
commands to the power supply using the SCPI commands and the
theory behind SCPI.
Hardware and Connection Setup
This section provides information on setting up the hardware and is
organized into setup for each hardware type. Once the setup has been
successfully completed, data can be sent to and responses received from
the power supply. Select which hardware interface to use and follow the
instructions and diagram for that hardware set up.
Configuring Remote Control Using RS-232
To configure remote control using RS-232:
1.
Use the top J4 connector of the two 8-pin RJ-45 jacks, as
shown in Figure 5-1, to connect to the RS-232 remote
interface.
2.
Connect from PC to power supply using a cable that meets the
cabling specifications listed in Table 5-1.
Summary of Contents for Sorensen XG
Page 2: ......
Page 22: ...Contents xx M370430 01 Rev B ...
Page 96: ...Local Operation 3 48 M370430 01 Rev B Figure 3 5 Series Operation ...
Page 102: ...Local Operation 3 54 M370430 01 Rev B ...
Page 210: ...Remote Operation 5 76 M370430 01 Rev B ...
Page 276: ...Communications Options 6 66 M370430 01 Rev B ...
Page 378: ...Rack Mount Options and Installation Instructions D 12 M370430 01 Rev B ...
Page 381: ......