Remote Operation
5-62
M370430-01 Rev B
Locking
and
Unlocking
the
Front
Panel
Locking out the front panel will prevent any of the buttons from
functioning. All the buttons and knobs on the front panel will display the
LOCL
L
OC
message to be display on the Current and Voltage displays if
pressed or rotated. This mode prevents any changes to the unit from the
front panel. See the following procedure to lock and unlock the front
panel.
The SCPI Commands for these instructions are:
[:]SYSTem[<channel>]:REMote:STATe {?|LOCal|REMote}
Where:
LOCal is used to set the front panel mode to local.
REMote is used to set the front panel into locked mode (remote).
For example:
SYST : REM: STAT REM
Front panel is locked (remote digital
programming mode only).
SYST : REM: STAT LOC
Front panel is unlocked.
SYST : REM: STAT ?
Query for status
Auto Sequence Programming
Auto Sequence programming lets you execute a program stored in
the power supply's memory. The program that can be stored in
memory can be composed of any of the SCPI commands described
in this Manual.
For example, Auto Sequence programming allows you to set the
timer to turn the power output of the supply Off or On after a time
interval or to program voltage sequences.
When a program is activated each command stored in the buffer is
executed as if the operator had sent the command by typing it in. A
variable delay time called dwell is spent between commands. The
dwell time can range from 0 seconds to 180 seconds. See “Setting
Dwell Time” on page 5-63.
The Auto Sequence program will be cleared after AC power is
turned off; however, a procedure exists for storing it in a text file
which can be reloaded at a later date.
Summary of Contents for Sorensen XG
Page 2: ......
Page 22: ...Contents xx M370430 01 Rev B ...
Page 96: ...Local Operation 3 48 M370430 01 Rev B Figure 3 5 Series Operation ...
Page 102: ...Local Operation 3 54 M370430 01 Rev B ...
Page 210: ...Remote Operation 5 76 M370430 01 Rev B ...
Page 276: ...Communications Options 6 66 M370430 01 Rev B ...
Page 378: ...Rack Mount Options and Installation Instructions D 12 M370430 01 Rev B ...
Page 381: ......