Quick Start

 

 

 

 

 

 

SPD1000X Programmable Linear DC 

Power Supply 

 

 

 

 

QS0501X-E02B 

 

 

 

 

 

 

 

 

 

 

 

 

2018 SIGLENT TECHNOLOGIES CO.

LTD 

 

Summary of Contents for SPD1000X Series

Page 1: ...SIGLENT Quick Start SPD1000X Programmable Linear DC Power Supply QS0501X E02B 2018 SIGLENT TECHNOLOGIES CO LTD ...

Page 2: ......

Page 3: ...GIES Declaration SIGLENT products are protected by patent law in and outside of the Peoples Republic of China SIGLENT reserved the right to modify or change the specifications and price of the product Information in this publication replace all previous corresponding material Any copying extracting or translation of the content of this manual is not allowed without permission from SIGLENT ...

Page 4: ...use the correct type of fuse before turning on the instrument Find the cause of the fuse failure before replacing the fuse and connecting the power cord Ground the instrument The instrument is grounded through the protective earth conductor of the power cord To avoid electric shock the grounding conductor must be connected to the earth ground Make sure that the instrument is properly grounded befo...

Page 5: ...n Operate in an electrostatic discharge protective area environment to avoid damages induced by static discharges Always ground both the internal and external conductors of the cable to release static before connecting Do not operate in an explosive atmosphere To avoid personal injury or damage to instrument please do not operate in an explosive atmosphere Keep surface of the product clean and dry...

Page 6: ...irect injury or hazard that may happen WARNING Indicates potential injury or hazard that may happen CAUTION Indicates potential damage to the instrument or other property that may happen Symbols may appear on the product Hazardous Hazardous Power Protective Earth Terminal Warning Earth Ground Power Switch ...

Page 7: ...ues of 16 V 8 A while the SPD1305X has a maximum output values of 30 V 5 A Both models have remote sense capability output short circuit and overload protection Figure 1 Side view Main features Single high precision programmable output SPD1168X 16 V 8 A total power is 128 W SPD1305X 30 V 5 A total power is 150 W Compact easy to use powerful ideal for bench power supply applications Stable Reliable...

Page 8: ...nction maximum compensation up to 1V Four varieties of input line voltage values include 100V 110V 220V and 230V to satisfy user requirements Intelligent temperature controlled fan effectively reduces noise Clear graphical interface with waveform display 5 internal system parameters save recall support for data storage space expansion Uses EasyPower PC software real time control via USB LAN suppor...

Page 9: ...and Declaration I General Safety Summary II General Safety Summary IV SPD1000X Brief Introduction V General Inspection 1 The Front Panel 2 The Rear Panel 5 Connect Power 7 User Interface 9 Output Inspection 11 Fuse Replacement 12 Troubleshooting 13 Contact SIGLENT 14 ...

Page 10: ...SIGLENT VIII SPD1000X Quick Start ...

Page 11: ...ts The consigner or carrier is responsible for damages to the instrument resulting from shipment SIGLENT will not provide free maintenance or replacement for shipping damages 2 Inspect the instrument If there is damage defects or failures in electrical and mechanical tests of the product please contact your nearest SIGLENT sales representative 3 Check the accessories Please check the accessories a...

Page 12: ...SIGLENT 2 SPD1000X Quick Start The Front Panel Figure 2 The front panel of the SPD1168X ...

Page 13: ...stem message interface Press the button for 1 second or longer to activate the lock function Press the button briefly to enter the timer interface Press the left button to move the cursor from left to right press the right button to move the cursor in the opposite direction In the timer interface or main interface press the On Off button briefly to turn on off the timer Press the button for 1 seco...

Page 14: ...e button to enable disable the channel output 4 Output Terminal Physical output connections to the external circuit 5 Ground Terminal This terminal is connected to the instrument chassis and ground wire and is in grounded state 6 Sense terminal Used to sense the actual voltage at the load This allows the source to compensate the voltage drop caused by the leads between the power supply and the loa...

Page 15: ... SPD1000X Quick Start 5 The Rear Panel Figure 3 The rear panel of the SPD1000X 1 Warning message To note to ground the instrument and non professional personnel should not disassemble the instrument and so on ...

Page 16: ...C input power 4 Fuse The needed specified fuse relate to the input voltage Please refer to the AC input voltage description 5 AC line power selection switch AC Input Voltages 100 120 220 230 V 6 LAN interface Connect the local network by RJ45 interface 7 USB device Connect the instrument as slave device to external USB device such as USB storage device computer 8 Fan ...

Page 17: ...10 50 60 Hz 220 VAC 10 50 60 Hz 230 VAC 10 50 60 Hz Please connect the power carefully follow the steps below 1 Check the input power Make certain that the AC line power to be connect to the instrument meets the requirements in Table 1 2 Check the voltage selector at the rear panel Make certain that the voltage selector setting at the rear panel of the instrument matches the actual input voltage 3...

Page 18: ...e instrument to AC power supply using the power cord provided in the accessories Then press the button to turn on the power WARNING Before switching the input power supply voltage please disconnect the power supply before setting the voltage selector To the appropriate gear WARNING To avoid electric shock make sure that the instrument is correctly grounded 8 SPD1000X Quick Start ...

Page 19: ...SIGLENT User interface Figure 4 The user interface 1 Channel output state 2 Remote sense mode 3 LAN connection icon 4 USB connection icon 5 Output mode SPD1000X Quick Start 9 ...

Page 20: ...SIGLENT 6 Output programmed values 7 Measured output values 8 Timer state 10 SPD1000X Quick Start ...

Page 21: ...int from the minimum 0 V to the maximum value 30 V 2 Check the output current 1 Turn on the power and make sure the voltage setting is not zero 2 Connect the output terminals short with an insulated wire that can handle 10 A or more 18 AWG single core for example 3 Activate the output by pressing the on off button The low impedance shorted output will cause the instrument to enter current control ...

Page 22: ...st the power voltage selector manually to select the correct voltage scale 4 Take out the fuse and replace it with the specified fuse for the corresponding relations between the input voltage and fuse specification refer to the input power requirement at the rear panel 5 Re insert the fuse holder into the power socket please pay attention to the direction WARNING To avoid personal injuries unplug ...

Page 23: ...t is abnormal 1 Check whether the maximum output power of the scale currently selected fulfills the load requirement If yes go to the next step 2 Check the cable connecting the load and power supply for short circuits 3 Check whether the load is normal 4 Check whether the current setting value of this scale is proper If it is too low increase it 5 If the problem remains please contact SIGLENT 3 Th...

Page 24: ...entamerica com Headquarters SIGLENT TECHNOLOGIES CO LTD Blog No 4 No 5 Antongda Industrial Zone 3rd Liuxian Road Bao an District Shenzhen 518101 China Tel 86 755 3688 7876 Fax 86 755 3359 1582 sales siglent com www siglent com ens Europe SIGLENT TECHNOLOGIES EUROPE GmbH Liebigstrasse 2 20 Gebaeude 14 22113 Hamburg Germany Tel 49 0 40 819 95946 Fax 49 0 40 819 95947 info eu siglent com www siglente...