Remote Operation
5-8
M370430-01 Rev B
RS-485 Communication Cable with Two RJ-45s
Use the top connector of the two 8-pin RJ-45 jacks, as shown in Figure
5-1, to connect to the RS-485 remote interface. Communication cable
with two RJ-45 shielded connectors (see
Figure 5-3)
connecting the
master unit to the slave unit. The cable length should be 9.84 feet (3 m)
or longer. The pinouts for the RJ-45 plug on the master unit are the same
as described in
Table 5-7.
Table 5-7
RJ-45 Plug on Slave Unit
Pin
Name
Description
1, 2
NC
No connection
3
RXD+
Receive data
Twisted
pair
4
RXD-
Receive data
5
TXD+
Transmit data
Twisted
pair
6
TXD-
Transmit data
7
GND
Ground
8
NC
No connection
Master unit (J6)
Slave unit (J4)
Figure 5-6
RS-485 Communication Cable from Master to Slave Unit
Completing the Setup
To complete the setup:
Configure the XG/XTR to use the 485 remote interface and setup
the terminal that will be used on the connected PC.
See sections entitled “Selecting the Appropriate Communication
Port” on page 5-24 and “Terminal Configuration” on page 5-21 for
more details.
RXD+
RXD
–
TXD+
TXD
–
GND
RXD+
RXD
–
TXD+
TXD
–
Summary of Contents for Sorensen XG
Page 2: ......
Page 22: ...Contents xx M370430 01 Rev B ...
Page 96: ...Local Operation 3 48 M370430 01 Rev B Figure 3 5 Series Operation ...
Page 102: ...Local Operation 3 54 M370430 01 Rev B ...
Page 210: ...Remote Operation 5 76 M370430 01 Rev B ...
Page 276: ...Communications Options 6 66 M370430 01 Rev B ...
Page 378: ...Rack Mount Options and Installation Instructions D 12 M370430 01 Rev B ...
Page 381: ......