Cataya Special BAH0109-1 02.21
12.3.3 Check the chain tension
Adhere to the inspection intervals,
see section "Maintenance schedule", page 191.
1. Open the function flap
see section 12.4.1, page 202.
2. Relieve the chain drive.
3. Pull the chain down in the marked area.
4. Push the chain up in the marked area.
5. Measure the difference.
Fig. 242
Maximum chain sagging: 8 mm
6. Tension the drive chain.
7. Close the function flap.
Fig. 243