Pike Technical Manual
V5.2.0
359
Configuration of the camera
The
ProfileID
is equivalent to the memory channel number and specifies the
profile number to store settings to or to restore settings from. In any case profile
#0 is the hard-coded factory profile and cannot be overwritten.
After an initialization command, startup or reset of the camera, the
ProfileID
also indicates which profile was loaded on startup, reset or initialization.
Store
To store the current camera settings into a profile:
1.
Write the desired
ProfileID
with the
SaveProfile
flag set.
2.
Read back the register and check the
ErrorCode
field.
Restore
To restore the settings from a previous stored profile:
1.
Write the desired
ProfileID
with the
RestoreProfile
flag set.
2.
Read back the register and check the
ErrorCode
field.
Set default
To set the default profile to be loaded on startup, reset or initialization
1.
Write the desired
ProfileID
with the
SetDefaultID
flag set.
2.
Read back the register and check the
ErrorCode
field.
Error codes
Note
•
The default profile is the profile that is loaded on power-
up or an INITIALIZE command.
•
A save or load operation delays the response of the cam-
era until the operation is completed. At a time only one
operation can be performed.
ErrorCode #
Description
0x00
No error
0x01
Profile data corrupted
0x02
Camera not idle during restore operation
0x03
Feature not available (feature not present)
0x04
Profile does not exist
0x05
ProfileID out of range
0x06
Restoring the default profile failed
0x07
Loading LUT data failed
0x08
Storing LUT data failed
Table 195: User profiles:
Error codes