Pike Technical Manual
V5.2.0
115
Camera interfaces
Outputs
Output features are configured by software. Any signal can be placed on any out-
put.
The main features of output signals are described below:
IntEna
Output signal
Opto-
Coupler
Polarity
selectable
via software
Operation state
read
FVal
Busy
Operation state
read
Output
mode
selectable
via software
Note
•
Switching trigger delay to ON also switches external Trig-
ger_Mode_0 to ON.
•
This feature works with external Trigger_Mode_0 only.
Note
For a general description of the
outputs
and
warnings
see the
1394 Installation Manual,
Chapter
Pike output description.
Signal
Description
IntEna (Integration Enable) signal
This signal displays the time in which exposure was
made. By using a register this output can be
delayed by up to 1.05 seconds.
Fval (Frame valid) signal
This feature signals readout from the sensor. This
signal Fval follows IntEna.
Busy signal
This indicator appears when the exposure is being
made; the sensor is being read from or data trans-
mission is active. The camera is busy.
Table 29: Output signals
Figure 61: Output block diagram