Pike Technical Manual
V5.2.0
323
Configuration of the camera
Other bits in this register might be set or toggled: just ignore these bits.
Maximum resolution
This register indicates the highest resolution for the sensor and is read-only.
Note
•
Excessive polling of this register may slow down the
operation of the camera. Therefore the time between two
polls of the status register should not be less than 5 mil-
liseconds. If the time between two read accesses is lower
than 5 milliseconds the response will be delayed.
•
Depending on shutter and isochronous settings the sta-
tus flags might be set for a very short time and thus will
not be recognized by your application.
Register
Name
Field
Bit
Description
0xF1000100
CAMERA_STATUS
Presence_Inq
[0]
Indicates presence of this fea-
ture (read only)
---
[1..23]
Reserved
ID
[24..31] Implementation ID = 0x01
0xF1000104
---
[0..14]
Reserved
ExSyncArmed
[15]
External trigger enabled
---
[16..27] Reserved
ISO
[28]
Isochronous transmission
---
[29..30] Reserved
Idle
[31]
Camera idle
Table 156: Advanced register:
Camera status
Note
This register normally outputs the MAX_IMAGE_SIZE_INQ For-
mat_7 Mode_0 value.
This is the value given in the specifications tables under
Picture size (max.)
Register
Name
Field
Bit
Description
0xF1000200
MAX_RESOLUTION
MaxHeight
[0..15]
Sensor height
(read only)
MaxWidth
[16..31] Sensor width
(read only)
Table 157: Advanced register:
Maximum resolution
inquiry