Pike Technical Manual
V5.2.0
131
Description of the data path
Dual-tap offset adjustment with SmartView (1.10 or greater)
Prerequisites:
•
Lens cap
•
Test sheet with continuous b/w gradient
•
Only following cameras: Pike F-032/Pike F-100/Pike F-210/Pike F-421/
Pike F-505/Pike F-1100/Pike F-1600
•
Pike camera with defocused lens
•
Pike color cameras set to RAW8 or RAW16 (debayering: none)
•
In case of using AOI, be aware that the middle vertical line (+/- 20 pixel) is
part of the AOI.
•
First do offset adjustment, then do gain adjustment.
To carry out an adjustment (offset adju gain adjustment) in SmartView,
perform the following steps:
1.
In SmartView click
Extras
Adjust channels...
or use
Alt+Ctrl+A
.
Figure 70: Example of channel adjustment: Pike F-032B
before
after