Pike Technical Manual
V5.2.0
110
Camera interfaces
The following sketch illustrates the series of blinks for a Format_7_error_1:
You should wait for at least 2 full cycles because the display of blinking codes
starts asynchronously - e.g. on the second blink from S2.
Control and video data signals
The inputs and outputs of the camera can be configured by software. The differ-
ent modes are described below.
Class S1
Error code S2
Warning
1 blink
DCAM
2 blinks
MISC
3 blinks
FPGA
4 blinks
Stack
5 blinks
FPGA boot error
1-5 blinks
Stack setup
1 blink
Stack start
2 blinks
No FLASH object
1 blink
No DCAM object
1 blink
Register mapping
3 blinks
VMode_ERROR_STATUS
1 blink
FORMAT_7_ERROR_1
2 blinks
FORMAT_7_ERROR_2
3 blinks
Table 23: Error codes
Figure 59: Warning and error states