Shutter register value
External Trigger input, after inverting opto coupler
Integration Time
External Trigger input,
after inv. Opto.
External Trigger input, as applied at input pin
External Trigger input, as applied at pin
Pike Technical Manual
V5.2.0
201
Controlling image capture
Bulk Trigger (Trigger_Mode_15)
Trigger_Mode_15 is an extension to the IIDC trigger modes. One external trigger
event can be used to trigger a multitude of internal image intakes.
This is especially useful for:
•
Grabbing exactly one image based on the first external trigger.
•
Filling the camera's internal image buffer with one external trigger with-
out overriding images.
•
Grabbing an unlimited amount of images after one external trigger (sur-
veillance)
The Figure below illustrates this mode.
Figure 108: Trigger_Mode_0 and 1