Page
83
of
92
Fastener Removed
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Fastener Removed” output assignment will go active when a fastener is removed by the
operator. The controller must be configured to report disassembly for this output to work. It will
go inactive when the next fastening is started (the torque exceeds the threshold value) or a Job
reset.
Pulses
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Pulses” output assignment will output the pulse count value of the most recent rundown.
The value will be cleared to 0 at the start of a new fastening cycle or a Job reset.
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Pulses Ok” output assignment will go active at the completion of a fastening that has an
acceptable pulse count. It will go inactive when the next fastening is started (the torque
exceeds the threshold value) or a Job reset.
Pulses NOk
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Pulses NOk” output assignment will go active at the completion of a fastening that has an
unacceptable pulse count. It will go inactive when the next fastening is started (the torque
exceeds the threshold value) or a Job reset.