the input value changes and it is non-zero the date and time of the controller will be set to the
new value.
Set Date/Time (word swap)
Supported Feature
Bus Element
Bit
0-31
Polarity
N.O./N.C. Width Offset
√
√
√
√
The “Set Date/Time (word swap)” assignment is the same as the “Set Date/Time” assignment
except the high and low words (16bit) are swapped prior to evaluation. This is to correct the
mixed endianness of some PLC. See the “Set Date/Time” for behavior.
Verify PSet
Supported Feature
Bus Element
Bit
0-31
Polarity
N.O./N.C. Width Offset
√
√
√
√
√
The “Verify PSET” input will compare the current parameter set to the input value. Uses the width
parameter limit the width of the input bits read. The minimum width is 1 and the maximum is 8.
After the input is read the offset parameter will be added to the value do get the actual
parameter set number. If the parameter set input value does not match the current parameter
of the controller the tool will be disabled.
Clear Results
Supported Feature
Bus Element
Bit
0-31
Polarity
N.O./N.C. Width Offset
√
√
√
√
The “Clear Results” assignment will clear the latest results outputs (Ok, Nok, etc.) on the same
bus.
Log Change
Supported Feature
Bus Element
Bit
0-31
Polarity
N.O./N.C. Width Offset
√
√
√
√
The “Log Change” assignment will add entries to the controller event log when the input
changes.
Decrement Batch
Supported Feature
Bus Element
Bit
0-31
Polarity
N.O./N.C. Width Offset
√
√
√
√
The
“Decrement Batch” assignment will remove the latest OK rundown from the current running
JOB. This will cause the JOB count to be reduced by one.