Page
62
of
92
IPC (URYU Electric Pulse Tool) Specific Fault Codes
CODE Fault Type
Description
Possible Causes
FP01
Torque signal out of
Range
Tool torque signal voltage
is beyond electrical limits
•
Tool not connected
•
Faulty tool cable
•
Faulty transducer
•
Transducer electronics not
calibrated
•
Faulty tool/controller
electronics or wiring
FP02
Torque tare value
out of range
Tool torque signal no load
voltage is out of range
•
Faulty tool cable
•
Transducer electronics
significantly out of calibration
•
Faulty transducer
FP03
Torque Cal signal
out of Range
Tool does not respond to
the full scale voltage CAL
single
•
Tool not connected
•
Faulty tool cable
•
Faulty transducer
•
Transducer electronics not
calibrated
•
Faulty tool/controller
electronics or wiring
FP04
Tool Not
Connected
Tool communication
timeout
•
Tool not connected
•
Faulty tool cable
•
Faulty tool electronics or
wiring