Page
79
of
92
Fastening Aborted
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Fastening Aborted” output assignment will go active at the completion of a fastening that
was aborted by the system. It will go inactive when the next fastening is started (the torque
exceeds the threshold value) or a Job reset.
Fastening Stopped
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Fastening Stopped” output assignment will go active at the completion of a fastening
that
was stopped by the user. It will go inactive when the next fastening is started (the torque
exceeds the threshold value) or a Job reset.
Batch Complete
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Batch Complete” output assignment will go active at the completion of a fastening that
satisfies the bolt count of a Job sequence. It will go inactive when the next fastening is started
(the torque exceeds the threshold value) or the job is reset.
Job Complete
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Job Complete” output
assignment will go active at the completion of a fastening that
satisfies all the sequences. It will go inactive when the next fastening is started (the torque
exceeds the threshold value) or the job is reset.