4.5 Controller
The controller menu is where all the settings for the iPC controller are configured. All the different
configuration capabilities are explained below:
4.5.1 Tool Setup
4.5.1.2 Tool Parameters
In this screen the user can set-up various tool functions.
For proper operation of the tool, this information must be entered each time a new tool is
connected to the controller.
Tool CAL:
Value stamped on
tool
•
CAL Ratio:
Calibration factor
for matching the torque
reading of the tool/controller
to a torque auditor
•
Maximum Torque:
Rated
maximum torque of the tool.
This is used when determining
the default PSets
•
Rated Speed:
Rated catalog
speed of the tool. (Optional
information only. Does not
affect the operation of the
tool)
•
Model Number:
(Optional
information only. Does not
affect the operation of the
tool)
•
Serial Number:
(Optional information only. Does not affect the operation of the
tool)
•
Reverse Speed:
The speed that the tool will run in reverse