Page
25
of
92
PSet Number
: Choose any current PSet already
configured in controller
Action:
•
None:
Stays in current sequence
•
Next:
Advances to next sequence set up after
count is reached
•
Count:
Fastener number required to complete
sequence
Once values are entered press
two times to return to Job screen
4.3.2 Advanced Options
Limit Reject Parameters
Enable:
Enable or Disable
Maximum Rejects:
Number of rejected fasteners allowed
Report Missing Fasteners
Add an option to each JOB that would allow us to report
any missing fasteners. When it is set the controller will report
an NOK rundown for each fastener that is defined in the JOB
but has not been ran. These NOK results will be reported
whenever a new job is started, AND the prior JOB is
incomplete.
These generated NOK results are treated like any other
fastening. They are displayed on the run screen, stored in
the results and transmitted on all protocols.