Page
82
of
92
Torque
(continued)
The “Torque” output assignment will output the final torque value of the most recent rundown.
The value will be cleared to 0 at the start of a new fastening cycle or a Job reset. At the end of
the fastening cycle the final torque will be truncated to an integer and output.
Torque (x10)
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Torque (x10)” output assignment will output the final torque value of the most recent
rundown. The value will be cleared to 0 at the start of a new fastening cycle or a Job reset. At
the end of the fastening cycle the final torque will be multiplied by 10, truncated to an integer
and output.
Torque (x100)
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Torque (x100)” output assignment will output the final torque value of the most recent
rundown. The value will be cleared to 0 at the start of a new fastening cycle or a Job reset. At
the end of the fastening cycle the final torque will be multiplied by 100, truncated to an integer
and output.
Angle
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Angle” output assignment will output the final
angle value of the most recent rundown.
The value will be cleared to 0 at the start of a new fastening cycle or a Job reset.
Rundown Saved to FTP Server
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Rundown Saved to FTP Server” output assignment will output the ID of the last rundown that