Page
21
of
92
4.2 PSet
Parameter Settings (PSets) control the fastening process. The following describes the different
fastening strategies and how-to setup the basic PSet parameters necessary to perform a fastening.
Up to 256 PSets are available.
4.2.1 Add New PSet
O
n Home Page press the
tab.
On
PSets
screen (right) press
to add a new
Pset.
Default PSets
(See Quick Setup)
Manage
(see Manage PSets)
On Add New PSet screen(below)enter appropriate
values.
PSet Number:
Current PSet to be added
Torque Units:
Unit of measure
In Cycle Torque:
Threshold value at which
tool is “In Cycle”
and results from the Rundown will be reported
Initial Speed:
This is the tool output speed in RPM before in-
cycle torque
Speed:
This is the tool output speed in RPM after in-cycle
torque
Time Limit(s) (sec):
Maximum allowable time tool is allowed to
run
Advanced Options:
(see check feature sets)
(
Once PSet values are entered press
to enter Edit Stage
screen below