Units selected in the PSet X10
▪
P: Angle Pass/Fail
•
‘P’ = Pass, ‘F’ = Fail
▪
HHHHH: Angle High Limit
•
Degrees
▪
LLLLL: Angle Low Limit
•
Degrees
▪
AAAAA: Angle Result
•
Degrees
▪
NAC%: Message End
▪
CR: Carriage return control character
▪
LF: Line feed control character
▪
NULL*: Null control character (*if option is selected)
•
UEC Serial Format (matches UEC 4800 and Gen3):
o
# 1 P BB TTT.T AAAA PPPP 0000 J CR NULL*
▪
#: Message Start
▪
1: Spindle Number (Always 1)
▪
P: PSet
•
PSet (
‘1’ –
‘9’) for PSets 1
-
9, (‘A’ –
‘Z’) for PSets 10
-35
▪
BB: Job Bolt Count
•
Total number of accepts during the Job
▪
TTT.T: Torque Result
•
Units selected in the PSet
▪
AAAA: Angle Result
•
Degrees
▪
PPPP: Pulse Count
▪
0000
▪
J: Judgment
•
‘@’ = Overall Pass, ‘H’ = Low Torque, ‘I’ = High Torque, ‘J’ = Low
Angle, ‘K = High Angle, ‘G’ = Fault During Fastening
▪
CR: Carriage return control character
▪