3.2 Quick Set Up:
(Default PSets from Tool)
On the Home Page press:
to accept default PSet Parameters.
This will generate three generic PSets for the tool connected to the
controller. It will
automatically use the 40%, 60%, and 80% of the rated maximum torque of the tool in a two-
stage Torque Control Pulse Monitor Strategy (TC_PM). A prompt will display rated Max Torque
and Max RPM of the connected tool for reference.
These Psets can be modified to meet
application requirements
.
4.) Home Page (Main Menu)