12.) Specifications
Mechanical:
Dimensions:
Width:
6.25 in
159 mm
Height:
15.75 in
400 mm
Depth:
12.5 in
316 mm
Weight:
15.65 lbs
7.1 kg
Operating Conditions:
Temperature:
32 to 122
ᵒ
F (0 to50
ᵒ
C)
Humidity:
Non-condensing
Ingress
Protection:
IP20
Electrical:
AC Power Source:
120 VAC, 1Φ/2 Φ
,
50/60 Hz.
24
0 VAC, 1Φ, 50/60 Hz.
84 W,3.5 Amps
Standards:
Safety Compliance:
EC Machinery Directive 2006/42/EC
EC Low Voltage Directive 2006/95/EC
EN 12100-1; EN 12100-12 Safety of Machinery
EN 60745-1; EN 60745-2-2 Hand-held motor operated tools
EMC
EC Directive of Electromagnetic Compatibility 2004/108/EC
EN 61000-6-4; EN 6100-6-2; Class A
RoHs
Reduction of Hazardous Substances 2002/95/EC
Markings
CE
13.) Trouble Shooting
Issue:
SD Card initializing
Soultion:
The rear SD card can be used to easily move the software, firmware, configuration, and
rundowns to a new controller in the event of hardware failure. This allows the controller to be
replaced with a new unit while retaining all the rundown information and configuration
settings. Remove the rear SD card from the damaged unit and insert it into a functioning unit to
perform the replacement. It is highly recommended that the controller settings are backed up
and saved by exporting the controller to a USB flash drive.
----------------------------------------------------------------------------------------------------------------------------- ---------------
Issue:
System port IP Address Drivers
Solution: NOTE:
In the event the RNDIS drivers do not install themselves, the following are the
steps to install new drivers in order to get the system port working.
RNDIS driver is a part of the Windows 7 operating system, but the OS fails to detect it
automatically. The following steps will help the user to install the RNDIS driver: