Page
30
of
92
4.5.1.3 Disassembly
Report Disassembly:
When enabled this will show
disassembly and angle torque values
Threshold Torque:
Value at which the tool is in cycle
disassembly value will be reported
Torque Units:
Choose unit of measure
Decrement Fastener Count:
If Disassembly is detected the
the fastener count in JOBS
Never:
Decrement count will be ignored
Always:
Decrement will always be active
Disable on Dissasembly:
If disassembly is detected the tool
will be disabled
Judgment Delay:
Amount of time after final pulse
in
disassembly that determines disassembly has been
completed
4.5.2 Tool Service
Cycles:
Pre-set service intervals that can be tracked by cycle
count
Pulses
: Pre-set service intervals that can be tracked by pulse
count
Cycle Limit x1000:
Pulse Limit x1000:
Service Due Action:
Four options are available
No Action
:
No Action will be taken
Log Error
:
Errors will be saved on Service Log
Display Error:
Calibration/Service message will appear on upper
LED display between each rundown. Tool remains functional
Disable Tool:
Disable tool in preset Service period. Exceeded
(date/time) LED warning appears on the controller