![Abicor Binzel iROB 501 PRO Original Operating Instructions Download Page 96](http://html2.mh-extra.com/html/abicor-binzel/irob-501-pro/irob-501-pro_original-operating-instructions_5036310096.webp)
EN
-
96
10 Faults and troubleshooting
iROB
®
501 PRO
E-
700
1
Excess current has been
detected on the output side of
the welding power source.
► Check that the contact tip at the end of the torch is not
touching the component.
► Check all connecting cables for abnormalities (e.g.,
short circuits).
The error message is canceled when the welding power
source is switched off.
E-
710
1
Phase "W" on the primary
power supply side is not
connected.
► Check that the primary side voltage supply is free of
faults.
The error message is canceled when the welding power
source is switched off.
E-
840
1
The temperature of the pull-feed
motor has exceeded the
permissible range.
► Ensure that the wires are not stuck and that there are no
other abnormalities in the welding torch or wire feeder.
► Ensure that the welding torch or the supply hose is not
clogged.
The error message is canceled when the power switch is
turned off.
E-
985
1
Welding started before the
automatic position adjustment of
the Wire Buffer KINETIC was
finished.
► Repeat the automatic position adjustment of the Wire
Buffer KINETIC using the internal function F86.
E-
988
2
Automatic position adjustment of
the Wire Buffer KINETIC has
failed.
The error message is canceled when any button on the
control panel is pressed.
10.1 General faults on page EN
E-
989
1
The combination of the wire
feeder and welding process is
incorrect.
► To use the mX Kinetic welding procedure, connect to the
Controller KINETICWire feed control unit.
The error message is canceled when the power switch is
turned off.
E-
990
1
Controller KINETIC has a fault. ► Check the fault code of the Wire feed control unit and
the method for each fault.
Controller KINETIC Wire feed control unit operating
instructions
The error message is canceled when the power switch is
turned off.
E-
950 to
956
1
CAN communication fault
► Check whether the CAN communications line is firmly
plugged into the CAN communication connector’s CN3
connection for the welding power source.
► Check whether the CAN communications line is firmly
connected to the CNCAN terminal of the AC servo wire
feeder controller.
The error message is canceled when the power switch is
turned off.
E-
992 to
998
Tab. 43
Fault codes on the control panel and their remedy
Fault code
Type of fault
1 = alarm
2 = warning
Cause of fault
Measure