7.12.1 Welding parameter/internal function settings
The following content can be stored in the file "BINZEL_iROB_WELDING_PARAMETER.CSV":
— All welding parameters stored in the memory
— The values of the internal functions at the time of the data backup
The parameter set currently displayed on the control panel is not stored. (If necessary, store this to the
welding power source’s memory in advance.)
The welding parameters stored in the welding power source’s memory are arranged so as to list the job
numbers vertically and the relevant parameters horizontally.
Fig. 39
Parameter value
Parameters in job no. 1
Unused job numbers are indicated by a "-".
Jo
b n
o.
Tab. 40
Gap
Position
Description
Unit
Gap
Position
Description
Unit
A
job_num
Job no.
−255 to
−155,
1 to 100
AA
wmode_H
Process information
1
1
B
spot_time
Arc spot time
0.1 s
AB
wmode_L
Process information
2
1
C
prf_tim
Shielding gas
pre-flow time
0.1 s
AC
pre_feed
Starting wire feed
speed
0.1 m/min
D
pre_iset
Starting current
1 A
AD
wld_feed
Wire feed speed
0.1 m/min
E
pre_vset
Starting voltage
0.1 V
AE
cre_feed
End crater wire
feed speed
0.1 m/min
F
pre_uni_vset
Starting voltage
(synergetic)
1 ±
AF
ant_tim_adj
Backburn time
Adjustment
0.01 s
G
wld_iset
Welding current
1 V
AG
ant_vset_adj
Burnback voltage
adjustment
0.1 V
H
weld_vset
Welding voltage
0.1 V
AH
sldwn_adj
Creep time
adjustment
0.1 m/min
I
wld_uni_vset
Welding voltage
(synergetic)
1 ±
AI
up_slp_tim
Ramp-up time
0.1 s
J
cre_iset
End crater filling
flow
1 A
AJ
dwn_slp_tim
Ramp-down time
0.1 s
K
cre_vset
End crater filling
voltage
0.1 V
AK
pre_tim
Start time
0.1 s
L
cre_uni_vset
End crater filling
voltage (synergetic)
1 ±
AL
cre_tim
Crater time
0.1 s
M
aff_tim
Shielding gas post-
flow time
0.1 s
AM
prelset
(Reserved)
–
N
acr_char
Arc characteristic
1 ±
AN
prelsetPer
(Reserved)
–
O
wave_frq
Wave frequency
0.1 Hz
AO
CrelsetPer
(Reserved)
–
P
arc_char2
Arc characteristics
(reserved)
–
AP
TSCricklset
Torch trigger
Current adjustment
0
(OFF)
Q
en_ratio
EN ratio
1%
AQ
CrilsetStep1
One-click
adjustment value
1 A