9 Maintenance and cleaning
EN
-
89
9.5.3 Replacing the wire guide nozzle
1
Disconnect the Pull Feeder KINETIC from the power supply.
2
Open the front cover
.
3
4
Loosen the dowel screws (2×)
5
Remove the wire guide nozzle
6
Install the new wire guide nozzle
in the reverse order.
Fig. 47
Replacing the wire guide nozzle
A
Front cover
B
Wire guide nozzle
C
2× dowel screws M4 × 12
D
Pressure lever
A
D
C
B