iROB
®
501 PRO
9 Maintenance and cleaning
EN
-
85
9.2 Cleaning the device
Dirty air inlets and outlets can significantly impair the cooling of the device. Metallic dust can additionally
lead to insulation problems and short circuits in the electronics. Dust accumulation on the fan blade
and cooling elements leads to insufficient heat dissipation. In this case, the <Warning/temperature>
LED illuminates.
After replacing the
welding wire
Push Feeder KINETIC:
► Check the pressure scale and adjust the pressure.
Pull Feeder KINETIC:
► Check the pressure scale and adjust the pressure.
► Clean the wire guide in the inner guide. Replace worn components.
Wire Buffer KINETIC:
► Check the wire guide for wear and damage, clean, and replace
worn components.
No longer than
1,000 operating hours or
more frequently
depending on the
location
► Clean the device.
9.2 Cleaning the device on page EN
Every 5 years
► Have circuit board PCB7, the fan, and the relay replaced by the
service department.
1
Clean the device by blasting dry, reduced
compressed air through the ventilation slots from
the front.
2
Remove the left cover and the fan frame.
3
If the interior and the cooling element
(A)
are heavily
soiled, carefully clean the interior by blasting dry,
reduced compressed air through it.
4
Clean surfaces with water, alcohol, or neutral cleaner.
Do not use organic or chemical cleaning agents.
5
Dry the device and mount the cover.
6
Re-establish the power supply.
6.1 Establishing the power supply on page EN
A