7 Operation
iROB
®
501 PRO
Example of welding parameters for multi-pass welding (standard mode)
Wire diameter: 1.2 mm; shielding gas: 20% CO
2
+ Ar
Tab. 30
Example of welding parameters for multi-pass welding (standard mode)
Seam type
Number of
layers
Welding current
(A)
Arc voltage
(V)
Comments
1
100
20 to 21
Slight oscillation
2
280
26 to 27
Slight oscillation
3
280
26 to 27
Slight oscillation
4
280
26 to 27
Slight oscillation
5
280
26 to 27
Slight oscillation
6
280
26 to 27
Oscillation
7
280
26 to 27
Oscillation
1
100
20 to 21
Oscillation
2
130
21 to 22
Oscillation
3
130
21 to 22
Oscillation
4
130
21 to 22
Oscillation
5
130
21 to 22
Oscillation
6
120
19 to 20
Oscillation
1
100 to 200
20 to 22
No oscillation
2 to 8
200
24 to 25
No oscillation
9 to 12
180
24 to 25
No oscillation