To replace the wire guide:
4
5
Disconnect the wire guide
from the power fitting
and the wire conduit connector
6
Insert the new wire guide
and the wire conduit connector
.
7
Insert the guide rollers
on each side.
8
are in the recesses for the wire guide clamp
part of the wire guide clamp
with the hexagon sockets screws (2×)
of 0.44 Nm.
9
Secure the guide roller covers (2×)
with the hexagon socket screws with screw locking rings (4×)
10
with knurled screws (6×)
.
To replace the guide rollers:
11
Remove the guide rollers
.
12
Insert the new guide rollers
.
13
with knurled screws (6×)
.
Fig. 51
Removing the wire guide and guide rollers
G
8× guide rollers
H
Wire guide
I
Power fitting
J
2× O-ring
K
Wire guide clamp
L
Wire conduit connector
H
G
L
J
I
K