![Abicor Binzel iROB 501 PRO Original Operating Instructions Download Page 43](http://html2.mh-extra.com/html/abicor-binzel/irob-501-pro/irob-501-pro_original-operating-instructions_5036310043.webp)
iROB
®
501 PRO
7 Operation
EN
-
43
7.4 Preparing the welding process
4.1.1 Control elements on page EN
The following settings must be made before the welding process begins:
1
Check that the welding procedure is suitable for the welding wire material to be welded.
7.3.2 Overview of welding procedures on page EN
2
Set the welding wire material, shielding gas type, and welding speed.
3
Set the welding wire diameter.
7.4.1 Setting the welding procedure on page EN
4
Set the shielding gas pre-flow time.
5
Set the start parameters (welding current and welding voltage).
6
Set the main welding parameters (welding current and welding voltage).
7
Set the end crater filling parameter.
8
Set the shielding gas post-flow time.
9
Save the parameters.
7.4.1 Setting the welding procedure
4.1.1 Control elements on page EN
1
Select the desired procedure by pressing the <Welding procedure>
selection button.
2
Select the desired welding wire material by pressing the <Welding wire
material> selection button.
3
Select the desired shielding gas by pressing the <Shielding gas type>
selection button.
4
Select the desired diameter by pressing the <Welding wire diameter>
selection button.
5
Press the <Penetration control> button to switch on this function if required.
If the LED is on, the Penetration Control function is active.
If the LED is off, the Penetration Control function is inactive.
P.CONTR.