7.12.5 Importing backup data
The data stored in the welding power source is overwritten by the backup data import. If necessary, save
this data prior to conducting the import.
1
Set the main switch to <I>.
2
Insert the USB storage device into the USB port on the
control panel.
3
Press the <Safe> button.
The LED above the <Safe> button illuminates.
4
Twist the <Parameter setting> knob until <USB> appears
on the left-hand digital display.
5
Twist the <Parameter setting> knob counterclockwise until
the desired data backup is displayed.
— 1 = welding parameters
— 2 = internal function settings
— ALL: data backup 1 to 2
6
Press the <Safe> button.
The LED above the <Safe> button flashes.
7
Press <Enter>.
The data import starts.
The right-hand digital display changes during the data
backup.
Once the data backup is complete, "End" appears on the
right-hand digital display.