F23: setting the time period until stand-by mode
If the device is not used for a longer period of time, it can be automatically switched to stand-by mode. Power
consumption is reduced. When in stand-by mode, a dot blinks in both digital displays. All other displays and
operations are switched OFF. Any operation terminates stand-by mode and the device returns to normal
mode.
F24: setting the wire feed speed
ON function:
The welding current is automatically set as appropriate for the wire feed speed, even if the welding
procedure is changed via the <Shielding gas type> selection button. Each time the <Parameter selection>
button is pressed, the display switches back and forth between wire feed speed and welding current.
► Press the <Parameter selection> key and activate wire feed speed.
► Enter the value in the unit [0.1 m/min].
► By switching to the welding current display, it is possible to check which welding current value was
automatically set.
The nominal wire feed speed is between 0.6 m/min. and 22 m/min. These values may differ depending on
the welding process.
OFF function:
The wire feed speed is automatically set as appropriate for the welding current, even if the welding
procedure is changed via the <Shielding gas type> selection button. Each time the <Parameter selection>
button is pressed, the display switches back and forth between wire feed speed and welding current.
► Press the <Parameter selection> key and activate the welding current.
► Enter the value in the unit [1 A].
► By switching to the welding current display, it is possible to check which wire feed speed was
automatically set.
F25–F28: setting external outputs
For service engineers only.
F29–F32: setting external inputs
For service engineers only.
Adjustable range
0 to 10 min.
Default value
0 min.
Storage option
No
Description
Time after which the device is switched to standby mode.
0: function deactivated
Adjustable range
ON/OFF
Default value
OFF
Storage option
No
Description
OFF: current-based
ON: based on the wire feed speed