8 Specification
144
OI/RVG200-EN
Hybrid module
6 Analog 5 digital inputs
Analog block
Analog output
Digital output
Transmitter PSU
Digital input
Ethernet module
Physical medium
10 / 100BaseT
Protocols
TCP / IP, ARP, ICMP, FTP (server), HTTP,
MODBUS TCP (master / slave), SNTP
FTP server functions
Directory selection & listing
File upload / download
4,
independently
configurable
users
with
full
or
read-only access
Web server functions
Operator screen monitoring / selection
Remote monitoring of recording channels, analog /
digital signals, alarms, totalizers and archiving
RS485 serial communications module
Number of ports
1 as option
Connections
RS485, 2- or 4-wire
Protocol
MODBUS RTU slave + master
Isolation:
500 V DC from rest of recorder
EMC
Emissions & Immunity
Electrical
Power supply
100 to 240 V AC ±10 % (90 min. to 264 V max.)
50 / 60 Hz
24 V DC (23.0 to 24.5 V DC)
Power consumption
43 VA max.
Power interruption protection
No effect for interruptions of up to 20 ms
Number:
6, galvanically isolated
Configuration
options:
Analog output, digital output or
transmitter PSU
Configurable
current range:
0 to 20 mA
Maximum load:
750
Isolation:
500 V DC from any other I/O
Accuracy:
0.25 %
Voltage:
24 V (nominal)
Drive:
22.5 mA
Isolation:
500 V DC from any other I/O
22.5 mA at 24 V DC (nominal)
Isolation:
500 V DC from any other I/O
Number:
5
Type:
Volt-free switching inputs
Polarity:
Negative (closed switch contact
or 0 V = active signal)
Digital input
minimum pulse:
125 ms
Isolation:
500 V DC from any other I/O *
* No isolation between digital I/O on the same module
Meets
requirements of:
EN50081-2
EN50082-2
EN61326 for an industrial
environment