136 Technical data
High speed mode
Selection
High speed mode
of parameter
95.15 Special HW settings
improves control
performance at high output frequencies. We recommend it to be selected with output
frequency of 120 Hz and above.
This table gives the drive module ratings for 120 Hz output frequency and the maximum
output frequency for the drive ratings when
High speed mode
in parameter
95.15 Special
HW settings
is enabled: With output frequencies smaller than this recommended
maximum output frequency, the current derating is less than the values given in the table.
Contact ABB for operation above the recommended maximum output frequency or for the
output current derating with output frequencies above 120 Hz and below the maximum
output frequency.
Drive
module
type
ACS880-
07XT-
Deratings with selection High speed mode of parameter 95.15 Special HW settings
120 Hz output frequency
Maximum output frequency
Nominal use
Light-
duty use
Heavy-
duty use
Nominal use
Light-
duty
use
Heavy-
duty use
f
I
N
P
N
I
Ld
I
Hd
f
max
I
N
P
N
I
Ld
I
Hd
Hz
A
kW
A
A
Hz
A
kW
A
A
U
N
= 400 V
1010A-3
120
1010
544
997
746
500
760
435
729
541
1190A-3
120
1190
650
1167
878
500
892
460
857
637
1330A-3
120
1330
734
1316
1041
500
955
460
913
718
1610A-3
120
1610
915
1570
1274*
500
1159
653
1104
920*
U
N
= 500 V
1010A-5
120
1010
693
997
720
500
696
435
661
519
1160A-5
120
1160
822
1146
878
500
754
460
721
548
1310A-5
120
1310
916
1297
1041
500
850
580
788
666
1610A-5
120
1610
1153
1570
1274*
500
1012
736
938
754
U
N
= 690 V
0810A-7
120
810
753
791
678*
375
546
471
528
445*
0960A-7
120
960
920
929
837
375
552
460
534
482
1080A-7
120
1080
1025
1051
929
375
626
580
607
552
1320A-7
120
1320
1300
1297
1051*
375
828
736
791
644*
3AXD10000363510
f
Output frequency
f
max
Maximum output frequency with High speed mode
U
N
Nominal voltage of the drive
I
N
Continuous rms output current. No overload capability at 40 °C (104 °F)
P
N
Typical motor power in no-overload use.
I
Ld
Continuous rms output current allowing 10% overload for 1 minute every 5 minutes
I
Hd
Continuous rms output current allowing 50% overload for 1 minute every 5 minutes
*
Continuous rms output current allowing 30% overload for 1 minute every 5 minutes
Summary of Contents for ACS880-07XT Series
Page 1: ...ABB industrial drives Hardware manual ACS880 07XT drives 400 to 1200 kW ...
Page 4: ......
Page 12: ...12 ...
Page 20: ...20 Safety instructions ...
Page 26: ...26 Introduction to the manual ...
Page 54: ...54 Mechanical installation ...
Page 89: ...Electrical installation 89 PE 11 8 4 9 11 ...
Page 94: ...94 Electrical installation ...
Page 112: ...112 Fault tracing ...
Page 123: ...Maintenance 123 5 6 7 ...
Page 124: ...124 Maintenance 8 10 9 ...
Page 126: ...126 Maintenance 6 5 4 ...
Page 127: ...Maintenance 127 9 8 7 ...
Page 128: ...128 Maintenance 12 11 10 ...
Page 149: ...Dimensions 149 Dimension drawing examples Frame 2 R11 R10 with brake chopper ...
Page 150: ...150 Dimensions Frame 2 R11 R10 without brake chopper ...
Page 153: ...Dimensions 153 Location of input terminals ACS880 07XT 12 pulse ...
Page 154: ...154 Dimensions Location of output terminals ACS880 07XT R10 with du dt ...
Page 155: ...Dimensions 155 Location of output terminals ACS880 07XT R10 without du dt ...
Page 156: ...156 Dimensions Location of output terminals ACS880 07XT R11 with du dt ...
Page 157: ...Dimensions 157 Location of output terminals ACS880 07XT R11 without du dt ...
Page 158: ...158 Dimensions Location of PE terminals ACS880 07XT ...
Page 159: ...Dimensions 159 Location of resistor terminals ACS880 07XT R10 ...
Page 160: ...160 Dimensions Location of resistor terminals ACS880 07XT R11 ...
Page 168: ...www abb com drives www abb com drivespartners 3ABD00043579 Rev C EN 2018 01 01 Contact us ...