64 Guidelines for planning the electrical installation
Typical power cable sizes
The tables below give copper and aluminum cable types with concentric copper shield for
the drive modules with nominal current.
1) The cable sizing is based on max. 9 cables laid on a cable ladder side by side, three ladder type trays one
on top of the other, ambient temperature 30 °C (86 °F) PVC insulation, surface temperature 70 °C
(158 °F) (EN 60204-1 and IEC 60364-5-52). For other conditions, dimension the cables according to local
safety regulations, appropriate input voltage and the load current of the drive
.
Drive type
ACS880-
07XT-
IEC
1)
input and motor cabling
Cabling per basic module
Common cabling for the basic modules
Cu cable type
Al cable
type
Cu cable type
Al cable
type
mm
2
mm
2
mm
2
mm
2
U
N
= 400 V
1010A-3
3 × (3 × 120)
3 × (3 × 185)
4 × (3 × 185)
5 × (3 × 240)
1190A-3
3 × (3 × 150)
3 × (3 × 240)
4 × (3 × 240)
6 × (3 × 240)
1330A-3
3 × (3 × 185)
4 × (3 × 185)
5 × (3 × 240)
6 × (3 × 240)
1610A-3
3 × (3 × 240)
4 × (3 × 240)
6 × (3 × 240)
7 × (3 × 240)
U
N
= 500 V
1010A-5
3 × (3 × 120)
3 × (3 × 185)
4 × (3 × 185)
5 × (3 × 240)
1160A-5
3 × (3 × 150)
3 × (3 × 240)
4 × (3 × 240)
6 × (3 × 240)
1310A-5
3 × (3 × 185)
4 × (3 × 185)
5 × (3 × 240)
6 × (3 × 240)
1610A-5
3 × (3 × 240)
4 × (3 × 240)
6 × (3 × 240)
7 × (3 × 240)
U
N
= 690 V
0810A-7
3 × (3 × 95)
3 × (3 × 120)
4 × (3 × 150)
4 × (3 × 240)
0960A-7
3 × (3 × 120)
3 × (3 × 185)
4 × (3 × 185)
5 × (3 × 185)
1080A-7
3 × (3 × 150)
3 × (3 × 185)
4 × (3 × 240)
5 × (3 × 240)
1320A-7
3 × (3 × 185)
4 × (3 × 185)
5 × (3 × 240)
6 × (3 × 240)
Summary of Contents for ACS880-07XT Series
Page 1: ...ABB industrial drives Hardware manual ACS880 07XT drives 400 to 1200 kW ...
Page 4: ......
Page 12: ...12 ...
Page 20: ...20 Safety instructions ...
Page 26: ...26 Introduction to the manual ...
Page 54: ...54 Mechanical installation ...
Page 89: ...Electrical installation 89 PE 11 8 4 9 11 ...
Page 94: ...94 Electrical installation ...
Page 112: ...112 Fault tracing ...
Page 123: ...Maintenance 123 5 6 7 ...
Page 124: ...124 Maintenance 8 10 9 ...
Page 126: ...126 Maintenance 6 5 4 ...
Page 127: ...Maintenance 127 9 8 7 ...
Page 128: ...128 Maintenance 12 11 10 ...
Page 149: ...Dimensions 149 Dimension drawing examples Frame 2 R11 R10 with brake chopper ...
Page 150: ...150 Dimensions Frame 2 R11 R10 without brake chopper ...
Page 153: ...Dimensions 153 Location of input terminals ACS880 07XT 12 pulse ...
Page 154: ...154 Dimensions Location of output terminals ACS880 07XT R10 with du dt ...
Page 155: ...Dimensions 155 Location of output terminals ACS880 07XT R10 without du dt ...
Page 156: ...156 Dimensions Location of output terminals ACS880 07XT R11 with du dt ...
Page 157: ...Dimensions 157 Location of output terminals ACS880 07XT R11 without du dt ...
Page 158: ...158 Dimensions Location of PE terminals ACS880 07XT ...
Page 159: ...Dimensions 159 Location of resistor terminals ACS880 07XT R10 ...
Page 160: ...160 Dimensions Location of resistor terminals ACS880 07XT R11 ...
Page 168: ...www abb com drives www abb com drivespartners 3ABD00043579 Rev C EN 2018 01 01 Contact us ...