Program features 39
standards. Thus, the personnel safety of the complete machinery must not
be based on a specific frequency converter feature (such as the brake
control function), but it has to be implemented as defined in the application
specific regulations.
Motor
M
230 VAC
JCU unit
Mechanical brake
Brake control
hardware
Emergency
brake
X2
1
RO1
2
RO1
3
RO1
X3
11 DI5
13 +24 V
The brake on/off is controlled via signal
. The source for the brake
supervision is selected by parameter
.
The brake control hardware and wirings need to be done by the user.
• Brake on/off control through selected relay/digital output.
• Brake supervision through selected digital input.
• Emergency brake switch in the brake control circuit.
• Brake on/off control through relay output (i.e. parameter
setting is
• Brake supervision through digital input DI5 (i.e. parameter
setting is
, bit 4)