![ABB ACS850 series Firmware Manual Download Page 198](http://html1.mh-extra.com/html/abb/acs850-series/acs850-series_firmware-manual_3366110198.webp)
198 Parameters
97
97 User motor par
Motor values supplied by the user that are used in the motor
model.
97.01
Use given params
Activates the motor model parameters
.
Notes:
Parameter value is automatically set to zero when ID run is
selected by parameter
. The values of
…
are updated according to the motor
characteristics identified during the ID run.
This parameter cannot be changed while the drive is running.
0
Parameters
inactive.
0
1
are used in the motor
model.
1
97.02
Rs user
Defines the stator resistance
R
S
of the motor model.
0.00000 … 0.50000
p.u.
Stator resistance in per unit.
100000 =
1 p.u.
97.03
Rr user
Defines the rotor resistance
R
R
of the motor model.
Note:
This parameter is valid only for asynchronous motors.
0.00000 … 0.50000
p.u.
Rotor resistance in per unit.
100000 =
1 p.u.
97.04
Lm user
Defines the main inductance
L
M
of the motor model.
Note:
This parameter is valid only for asynchronous motors.
0.00000 …
10.00000 p.u.
Main inductance in per unit.
100000 =
1 p.u.
97.05
SigmaL user
Defines the leakage inductance
σ
L
S
.
Note:
This parameter is valid only for asynchronous motors.
0.00000 … 1.00000
p.u.
Leakage inductance in per unit.
100000 =
1 p.u.
97.06
Ld user
Defines the direct axis (synchronous) inductance.
Note:
This parameter is valid only for permanent magnet
motors.
0.00000 …
10.00000 p.u
Direct axis inductance in per unit.
100000 =
1 p.u.
97.07
Lq user
Defines the quadrature axis (synchronous) inductance.
Note:
This parameter is valid only for permanent magnet
motors.
0.00000 …
10.00000 p.u
Quadrature axis inductance in per unit.
100000 =
1 p.u.
97.08
Pm flux user
Defines the permanent magnet flux.
Note:
This parameter is valid only for permanent magnet
motors.
0.00000 … 2.00000
p.u
Permanent magnet flux in per unit.
100000 =
1 p.u.
97.09
Rs user SI
Defines the stator resistance
R
S
of the motor model.
0.00000 …
100.00000 ohm
Stator resistance.
100000 =
1 ohm
97.10
Rr user SI
Defines the rotor resistance
R
R
of the motor model.
Note:
This parameter is valid only for asynchronous motors.
0.00000 …
100.00000 ohm
Rotor resistance.
100000 =
1 ohm
No.
Name/Value
Description
FbEq
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Page 2: ......
Page 4: ......
Page 24: ...24 Start up...
Page 28: ...28 Control locations and operating modes...
Page 252: ...252 Fieldbus control...