Application macros 55
Default control connections for the Hand/Auto macro
X1
External power input
24 V DC, 1.6 A
+24VI
1
GND
2
X2
Relay output:
Ready
NO
1
COM
2
NC
3
X3
+24 V DC
+24VD
1
Digital I/O ground
DGND
2
Digital input 1:
EXT1 Stop/Start
DI1
3
Digital input 2:
EXT1 Direction
DI2
4
+24 V DC
+24VD
5
Digital I/O ground
DGND
6
Digital input 3:
EXT1/EXT2 selection
DI3
7
Digital input 4:
Constant speed 1
DI4
8
+24 V DC
+24VD
9
Digital I/O ground
DGND
10
Digital input 5:
EXT2 Direction
DI5
11
Digital input 6:
EXT2 Stop/Start
DI6
12
+24 V DC
+24VD
13
Digital I/O ground
DGND
14
Digital input/output 1:
Output: Ready
DIO1
15
Digital input/output 2:
Output: Running
DIO2
16
+24 V DC
+24VD
17
Digital I/O ground
DGND
18
Digital input/output 3:
Output: Fault(-1)
DIO3
19
X4
Reference voltage (+)
+VREF
1
Reference voltage (–)
-VREF
2
Ground
AGND
3
Analog input 1:
EXT1 Reference (Speed ref1)
(Current or voltage, selectable by jumper J1)
AI1+
4
AI1-
5
Analog input 2:
EXT2 Reference (Speed ref2)
(Current or voltage, selectable by jumper J2)
AI2+
6
AI2-
7
AI1 current/voltage selection
J1
AI2 current/voltage selection
J2
Thermistor input
TH
8
Ground
AGND
9
Analog output 1:
Current %
AO1 (I)
10
Analog output 2:
Speed %
AO2 (U)
11
Ground
AGND
12
X5
Drive-to-drive link termination
J3
Drive-to-drive link.
B
1
A
2
BGND
3
X6
Safe Torque Off. Both circuits must be closed for the drive
to start.
OUT1
1
OUT2
2
IN1
3
IN2
4
Control panel connection
X7
Memory unit connection
X205
T
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Page 2: ......
Page 4: ......
Page 24: ...24 Start up...
Page 28: ...28 Control locations and operating modes...
Page 252: ...252 Fieldbus control...