![ABB ACS850 series Firmware Manual Download Page 37](http://html1.mh-extra.com/html/abb/acs850-series/acs850-series_firmware-manual_3366110037.webp)
Program features 37
3)
Starting torque required at brake release is reached (
) AND brake
hold is not active (
Note:
With scalar control, the defined starting
torque has no effect.
4)
Brake is open (acknowledgement source selected by par.
is 1)
AND the brake open delay has elapsed (
). Start = 1.
5) 6) Start = 0 OR brake close command is active AND actual motor speed < brake close
) AND close command delay (
) has
elapsed.
7)
Brake is closed (acknowledgement = 0) AND brake close delay (
) has
elapsed. Start = 0.
8)
Start = 1 AND brake open request is on (source selected by
is 0)
AND reopen delay has elapsed.
9)
Brake is open (acknowledgement = 1) AND brake close delay has elapsed.
10)
Defined starting torque at brake release is not reached.
11)
Brake is closed (acknowledgement = 0) AND brake open delay has elapsed.
12)
Brake is closed (acknowledgement = 0).
13)
Brake is open (acknowledgement = 1) AND brake close delay has elapsed. Fault is
generated after brake close fault delay (
) has elapsed.
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Page 2: ......
Page 4: ......
Page 24: ...24 Start up...
Page 28: ...28 Control locations and operating modes...
Page 252: ...252 Fieldbus control...